Data sheet (419kb) | ||||||||||||||||
Signal conditioning is required where the output of a transducer needs to be boosted or changed into a form suitable for the monitor or logging device which will be used. A very wide range of gain adjustment ensures that our amplifiers are compatible with the vast majority of LVDT and strain gauge sensors available from any manufacturer. Modular 600 signal conditioning allows the customer to select the type and quantity if input cards required for the application from a number of different types available. The system can be supplied with optional monitor/display/data logger units if required. Firstly decide the type and quantity of modules required making sure to include any future requirements. Then decide if you need a monitor or data logger. Finally choose an appropriately sized housing with a power supply and blank panels to cover any unused slots. |
611 Strain gauge transducer amplifier | 611 technical manual (179kb) |
Compatible with | Most full bridge strain gauge transducers. Most amplified transducers from any manufacturer. | |
Number of channels | 2 | |
Supply voltage | ±15V, 60mA (plus transducer and output load) | |
Transducer excitation | 1V to 10V & ±15V (110mA maximum) | |
Output details | ±10V/ 4-20mA (loop resistance 0 Ohms to 450 Ohms) | |
Amplifier gain range | 1 to 2000 | |
Signal input range | -13V to 13V | |
Linearity error | ±0.02% F.S. (typical) | |
Electrical output bandwidth | 0 to 200Hz (10Hz with filter turned on) | |
Output ripple | 4mV peak-to-peak (typical) / 15uA peak-to-peak (typical) | |
Input impedance | 1G Ohms | |
Temperature coefficient (zero) | ±0.001% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.002% F.S. /°F (typical) | |
Approximate zero adjustment range | ±10V | |
Operating temperature range | 32°F to 140°F |
615 RDP PY series amplifier | 615 technical manual (171kb) |
Compatible with | Series PY Extreme environment non-contact displacement transducer | |
Number of channels | 1 | |
Supply voltage | ±15V, 60mA | |
Transducer excitation | 2.4kHz/4.8kHz/9.6kHz 10mA, (17Vrms maximum) | |
Output details | ±10V/ 4-20mA (loop resistance 0 Ohms to 450 Ohms) | |
Signal input range | 10mV to 10V | |
Linearity error | ±0.05% F.S. (typical) | |
Electrical output bandwidth | 0 to 160Hz (20Hz with filter turned on) | |
Output ripple | 10mV peak-to-peak (typical) / 120uA peak-to-peak (typical) | |
Input impedance | 1M Ohms | |
Temperature coefficient (zero) | ±0.003% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.011% F.S. /°F (typical) | |
Approximate zero adjustment range | ±10V | |
Operating temperature range | 32°F to 140°F |
621 LVDT amplifier | 621 technical manual (141kb) |
Compatible with | Any standard RDP LVDT. Most LVDTs from any manufacturer. | |
Number of channels | 2 | |
Supply voltage | ±15V, 65mA (typical) | |
Transducer excitation | 1.1V, 5kHz (1kHz to 10kHz with component change), 100mA | |
Output details | 10V/ 4-20mA (loop resistance 0 Ohms to 450 Ohms) | |
Amplifier gain range | 2.5 to 833 | |
Signal input range | 12mV to 4V | |
Linearity error | ±0.05% F.S. (typical) | |
Electrical output bandwidth | 0 to 500Hz | |
Output ripple | 10mV peak-to-peak (typical) / 100uA peak-to-peak (typical) | |
Input impedance | 100k Ohms | |
Temperature coefficient (zero) | ±0.003% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.003% F.S. /°F (typical) | |
Approximate zero adjustment range | 10V | |
Operating temperature range | 32°F to 140°F |
626 LVDT amplifier with Sum/Average/Difference calculation | 626 technical manual (110kb) |
Compatible with | Any standard RDP LVDT. Most LVDTs from any manufacturer. | |
Number of channels | 2 | |
Supply voltage | ±15V, 65mA (typical) | |
Transducer excitation | 1.1V, 5kHz, 100mA | |
Output details | ±10V/ 4-20mA (loop resistance 0 Ohms to 450 Ohms) | |
Amplifier gain range | 2.5 to 833 | |
Signal input range | 12mV to 4V | |
Linearity error | ±0.05% F.S. (typical) | |
Electrical output bandwidth | 0 to 500Hz | |
Output ripple | 10mV peak-to-peak (typical) / 100uA peak-to-peak (typical) | |
Input impedance | 100k Ohms | |
Temperature coefficient (zero) | ±0.003% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.003% F.S. /°F (typical) | |
Approximate zero adjustment range | ±10V | |
Operating temperature range | 32°F to 140°F |
628 1/4, 1/2 and full bridge strain gauge amplifier | 628 technical manual (260kb) |
Compatible with | 1/4, 1/2 and full bridge strain gauges. Most full bridge strain gauge transducers. | |
Number of channels | 1 | |
Supply voltage | ±15V, 70mA (plus transducer and output load) | |
Transducer excitation | 1V to 10V 110mA maximum | |
Output details | ±10V/ 4-20mA (loop resistance 0 Ohms to 400 Ohms) | |
Amplifier gain range | 1 to 80000 | |
Signal input range | -11V to 11V | |
Linearity error | ±0.02% F.S. (typical) | |
Electrical output bandwidth | 0 to 10/100/1k/10kHz | |
Output ripple | 40mV peak-to-peak (typical) / 80uA peak-to-peak (typical) | |
Input impedance | 100M Ohms | |
Temperature coefficient (zero) | ±0.0006% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.001% F.S. /°F (typical) | |
Approximate zero adjustment range | ±0.4V | |
Operating temperature range | 32°F to 140°F |
681 Limit trip module | 681 technical manual (142kb) |
Compatible with | The voltage output of any modular 600 amplifier. | |
Number of channels | 4 | |
Supply voltage | ±15V, 100mA | |
Output details | Voltage free relay contacts, TTL output | |
Contact rating | 30Vdc/125Vac,30/60VA | |
Operation time | 6ms | |
Signal input range | -10V to 10V | |
Accuracy | ±0.01% F.S. (typical) | |
Input impedance | 10M Ohms | |
Operating temperature range | 32°F to 140°F |
635 Digital display module | 635/636 technical manual (155kb) |
Number of channels | 24 (maximum) | |
Number of digits | 4 ½, red LED (0.39'') | |
Display update rate | 2.5Hz | |
Accuracy | ±0.03% F.S. (typical) | |
Linearity error | ±0.05% F.S. (typical) | |
Temperature coefficient (zero) | ±0.001% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.003% F.S. /°F (typical) | |
Operating temperature range | 32°F to 140°F |
636 Digital display module with max/min store for selected channel | 635/636 technical manual (155kb) |
Number of channels | 24 (maximum) | |
Number of digits | 4 ½, red LED (0.39'') | |
Display update rate | 2.5Hz | |
Accuracy | ±0.03% F.S. (typical) | |
Linearity error | ±0.05% F.S. (typical) | |
Temperature coefficient (zero) | ±0.001% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.003% F.S. /°F (typical) | |
Operating temperature range | 32°F to 140°F |
650 Serial interface and data logger module This device can log data to its own internal memory or to its serial port A free Microsoft Excel based data logger is available from our website which allows data to be logged to directly to an Excel Spreadsheet | 650/651 technical manual (267kb) |
Number of channels | 164 (maximum) | |
Data storage capacity | 650 = 10240 650ME1 = 65530 | |
Baud rate | 600 to 57600 | |
Number of digits | 4 ½, red LED | |
Display update rate | 1.0Hz | |
Accuracy | ±0.03% F.S. (typical) | |
Temperature coefficient (zero) | ±0.001% F.S. /°F (typical) | |
Temperature coefficient (span) | ±0.003% F.S. /°F (typical) | |
Operating temperature range | 32°F to 140°F |
631 Power supply |
Supply voltage | 93 to 264Vac, 80W | |
Operating temperature range | 32°F to 131°F |
Housings available. | 600 System technical manual (236kb) |
602 | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| |||||||||||||||||||||||
M603 | |||||||||||||||||||||||
| |||||||||||||||||||||||
M604 | |||||||||||||||||||||||
|
| ||||
Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. | ||||
RDP Electrosense 2216 Pottstown Pike Pottstown, PA 19465 USA Tel: 610-469-0850 Tel: 800-334-5838 Fax: 610-469-0852 Email: info@rdpe.com | - |